logo
제품 소개가스 센서

YJJ NH3/CR-50 Electrochemical Ammonia Gas Sensor Is Used As A Liquid Ammonia Leakage Sensor

인증
중국 ShenzhenYijiajie Electronic Co., Ltd. 인증
중국 ShenzhenYijiajie Electronic Co., Ltd. 인증
제가 지금 온라인 채팅 해요

YJJ NH3/CR-50 Electrochemical Ammonia Gas Sensor Is Used As A Liquid Ammonia Leakage Sensor

YJJ NH3/CR-50 Electrochemical Ammonia Gas Sensor Is Used As A Liquid Ammonia Leakage Sensor
YJJ NH3/CR-50 Electrochemical Ammonia Gas Sensor Is Used As A Liquid Ammonia Leakage Sensor YJJ NH3/CR-50 Electrochemical Ammonia Gas Sensor Is Used As A Liquid Ammonia Leakage Sensor

큰 이미지 :  YJJ NH3/CR-50 Electrochemical Ammonia Gas Sensor Is Used As A Liquid Ammonia Leakage Sensor

제품 상세 정보:
원래 장소: 스위스
브랜드 이름: YJJ
모델 번호: NH3/CR-50
결제 및 배송 조건:
최소 주문 수량: 1
가격: 협상 가능
포장 세부 사항: 박스 팩
배달 시간: 5-8 일
지불 조건: L/C, D/A, D/P, T/T, Western Union, MoneyGram
공급 능력: 1500

YJJ NH3/CR-50 Electrochemical Ammonia Gas Sensor Is Used As A Liquid Ammonia Leakage Sensor

설명
측정 범위: 0 ~ 100ppm 서비스 수명: 2 년 방송
출력 신호: 90±18nA/PPM 해결: 1 ppm
온도 범위: -10 ° C ~ 40 ° C 응답 시간 (T90): <60초
습도 범위: 15%~90% 기준선: 0ppm±4ppm
강조하다:

electrochemical ammonia gas sensor

,

liquid ammonia leakage detector

,

NH3 CR-50 gas sensor

Product Description:

YJJ NH3/CR-50 Electrochemical Ammonia Gas Sensor Is Used As A Liquid Ammonia Leakage Sensor

 

Features:

Ammonia gas sensor (NH3 sensor)

NH3/CR-200,NH3/MR-100,NH3/S-200,NH3/CR-1000,NH3/MR-1000,

NH3/CB-200 completely replaces 7AM, 7NH and A7AM in UK CITY

NH3/SB-200 completely replaces 3AM in UK CITY

NH3/MR-100 completely replaces 4AM in UK CITY

Technical parameters of NH3 sensor:

NH3/CR-200

Measurement range: 0 ~ 100ppm

Maximum load: 200ppm

Service life: 2 years in air

Output signal: 90±18nA/ PPM

Resolution: 1 PPM

Temperature range: -10°C to 40°C

Response time (T90) : <60sec

Humidity range: 15%to90%

Baseline: 0ppm±4ppm

Typical signal drift: <5% per 6 months

Recommended loading resistance: 10 Ohm

Bias voltage: not required

NH3/MR-100

Measurement range: 0 ~ 100ppm

Maximum load: 200ppm

Service life: 2 years in air

Output signal: 120±30nA/ PPM

Resolution: 1 PPM

Temperature range: -10°C to 40°C

Response time (T90) : <50sec

Humidity range: 15%to90%

Baseline: 0ppm±3ppm

Typical signal drift: <5% per 6 months

Recommended loading resistance: 10 Ohm

Bias voltage: not required

NH3/SR-200

Measurement range: 0 ~ 100ppm

Maximum load: 200ppm

Service life: 2 years in air

Output signal: 90±18nA/ PPM

Resolution: 1 PPM

Temperature range: -10°C to 40°C

Response time (T90) : <60sec

Humidity range: 15%to90%

Baseline: 0ppm±4ppm

Typical signal drift: <5% per 6 months

Recommended loading resistance: 10 Ohm

Bias voltage: not required

 

Specifications:

Detection of gas NH3
range 0-20ppm
Maximum limit of measurement 250ppm
The sensitivity 1±0.25 uA/ppm

 